D848 Acid Wash Color of Industrial Aromatic Hydrocarbons
• K0D848-A Sample Bottle, 1 ounce capacity, flat bottom, square, glass stoppered and graduated at 7mL and 28mL
• K0D848-B Individual Color Standard Bottle, 1 ounce capacity, flat bottom, square, glass stoppered, with a Specified number (0-14)
• K0D848-C Set of Fifteen (15) Color Standard Bottles numbered 0-14, empty
• K0D848-D Individual Color Standard Bottle, filled with specific number solution
• K0D848-E Set of Fifteen(15) Color Standard bottles (0-14) filled
• K0D848-F Color Standard Set with Case, lighted white plexiglass, full set of color standards sealed in bottles, and two sample bottles

D854 Determination of Specific Gravity
• K0D369-1 Specific Gravity Bottle, Gas-Lussac, 1mL, Unadjusted
• K0D369-2 Specific Gravity Bottle, Gas-Lussac, 2mL, Unadjusted
• K0D369-5 Specific Gravity Bottle, Gas-Lussac, 5mL, Unadjusted
• K0D369-10 Specific Gravity Bottle, Gas-Lussac, 10mL, Unadjusted

D888 Determination of Dissolved Oxygen in Water
• K0D888 Gas Collecting Tube, McLean type, 500mL, 3mm Stopcocks, graduated 2mL on Tube Ends

D889 Determination of Volatile Oil in Rosin
• K0D889 Distillation Receiver, 5mL in 0.1mL divisions, S/T 24/40

D891 Determination of Specific Gravity of Liquid Chemicals, Halogenated Organic Solvents,Ethylene Glycols, Propylene Glycols
• K0D891-25 Specific Gravity Bottle for Volatile Liquids, 25mL, Jacketed
• K0D891-50 Specific Gravity Bottle for Volatile Liquids, 50mL, Jacketed

D914 Testing Ethylcellulose and Methylcellulose
• K0D914 Apparatus for Testing Ethylcellulose

D941 Density and Relative Density (Specific Gravity) of Liquids by Lipkin Bicapillary Pycnometer
• K0D941 Pycnometer, side-arm type, 4.5 ±0.5mL, Weight less than 30g

D1015 Freezing Points of High Purity Hydrocarbons
• KD1015-FT Freezing Point Tube, Glass, with Hi-Vac Stopcock

D1016 Purity of Hydrocarbons from Freezing Points
• KD1015-AS Apparatus for Obtaining Sample, consisting of Dewar Flask, 50mL Condensing Tube, 3-way Stopcock, and Connecting Tubes 10mm OD with S/J 18/7 Ball and Socket Joints
• KD1015-NG Distilling Apparatus for Gaseous Substances, consisting of two Dewar Flasks, Distilling Tube, and Receiver
• KD1015-NL Distilling Apparatus for Normally Liquid Substances, consisting of Dewar Flask, Receiver, and 200mL Flask with Cap

D1018 Hydrogen in Petroleum Fractions
• KD1018-A Absorber Only, Turner Type
• KD1018-B Lamp Burner, S/T 14/20 Joints, Concentric Tubes
• KD1018-CH Hydrogen Determination Chimney
• KD1018-D-1 Erlenmeyer Flask, 14/10 S/T Outer Joint, 25mL
• KD1018-D-2 Standard Burner, 14/10 S/T Inner Joints
• KD1018-D-3 Chimney for Lamp Hydrogen Apparatus
• KD1018-E Absorption Bulbs
• KD1018-F Drierite U-Tube

D1065 Determination of Unsaponifiable Matter In Gum and Wood Rosin
• KD1065 Extraction Apparatus, Ether, S/T 24/40, 400mm Condenser, 250mL Flask

D1072 Total Sulfur in Fuel Gases
• KD1072-B Burner, S/T 14/10 Joint, Gas
• KD1266-C Chimney, S/T 14/10 and S/T 24/40 Joints
• KD1266-A Absorber, S/T 24/40 Joints, Parallel Chambers, AU Shape
• KD1266-ST Spray Trap, S/T 24/40 Joint, 65mm OD

D1091 Phosphorus Lubricating Oils s in And Additives
• KD1091 Flask, Kjeldahl, Digestion, 300mL, with Ground Glass Stopper

D1093 Centrifuge Tube, 100mL
• K00D96-8 Centrifuge Tube, Conical, A8-Inch (203mm), 100mL

D1120 Determination of Equilibrium Boiling Point of Engine Antifreezes Miscible With Water
• KD1120 Distillation Apparatus, 100mL Flask, 200mm Condenser, S/T 19/38

D1168 Testing Hydrocarbon Waxes for Electrical Insulation
• KD1168 Dilatometer, 0-2mL in 0.02mL divisions, S/T 14/20 Joint, 2mm Stopcock

D1173 Test For Foaming Properties of Surface-Active Agents
• KD1173 Pour Foam Test Apparatus, Ross-Miles, 200mL Pipette, Receiver graduated at 50mL and 250mL, Teflon Stopcocks, 2mm and 6mm Bore, Jacketed

D1217 Density and Relative Density of Liquids By Bingham Pycnometer
• KD1217-P Pycnometer, Bingham type, Stoppered, 25mL 1.0 – 1.1mm neck
• KD1217-PC Pycnometer Cleaning Apparatus, Hot Chromic Acid, consisting of 3-way Stopcock with Joint Inside Chamber

D1266 Sulfur in Petroleum Products (Lamp)
• KD1266-A Absorber, S/T 24/40 Joints, Parallel Chambers, AU shape
• KD1266-C Chimney, S/T 14/10 and S/T 24/40 Joints
• KD1266-ST Spray Trap, S/T 24/40 Joint, 65mm OD
• KD1266-SF Standard Flask, 25mL, S/T 14/10 Joint, with Hooks
• KD1266-FA Flask for Aromatic Samples with Side Arm
• KD1266-SB Standard Burner, S/T 14/10 Joints
• KD1266-BA Burner for Aromatic Samples

D1347 Standard Method of Testing Methylcellulose
• KD914 Apparatus for Testing Ethylcellulose

D1394 Jones-Blair Reductor
• KD1394 Column, Jones-Blair Reductor, 19mm ID x 450mm Long, 4mm stpk

D1480 Density and Relative Density of Viscous Materials by Bingham Pycnometer
• KD1480 Pycnometer, Bingham Type, Stoppered, 2mm ID neck, 10mL

D1481 Density and Relative Density of Viscous Materials by Lipkin Bicapillary Pycnometer
• KD1481 Pycnometer, Side-Arm Type, Weight less than 35 grams, 10mL

D1505 Density Gradient Determination
• KD1505-C Density Gradient Column, Jacketed, 38mm ID x 44″ long
• KD1505-F Density Float (specify exact density and color identification)

D1541 Iodine Flasks
• K00D29-125 Iodine Flask, 125mL, S/T 24/40 Mercury Seal w/Hollow Stopper
• K00D29-250 Iodine Flask, 250mL, S/T 24/40 Mercury Seal w/Hollow Stopper
• K00D29-300 Iodine Flask, 300mL, S/T 24/40 Mercury Seal w/Hollow Stopper
• K00D29-500 Iodine Flask, 500mL, S/T 24/40 Mercury Seal w/Hollow Stopper
• K00D29-1000 Iodine Flask, 1000mL, S/T 24/40 Mercury Seal w/Hollow Stopper

D1607 Sampling Nitrogen Dioxide in Small Concentrations
• KD1607 Gas Bubbler Apparatus, S/T 29/42, S/J 18/7, Coarse Pencil Frit

D1638 Specific Gravity of Pigments, Drying Oils, Varnishes, Resins, etc.
• K0C135-10 Pycnometer, 10mL, with Thermometer and Cap
• K0C135-25 Pycnometer, 25mL, with Thermometer and Cap
• K0C135-50 Pycnometer, 50mL, with Thermometer and Cap
• K0C135-100 Pycnometer, 100mL, with Thermometer and Cap

D1839 Amyl Nitrate in Diesel Fuels
• KD1839-F Flask, Distilling, 300mL, S/T 24/40 Joint
• KD1839-DC Distillate Collector, S/T 24/40 Joints
• KD1839-C Condenser, Allihn, 300mm, S/T 24/40 Joint
• KD1839-VF Volumetric Flask, 100mL, Stoppered
• KD1839-FF Funnel for Volumetric Flask

D1949 Separation of Tetraethyllead and Tetramethyllead in Gasoline
• KD1949-F Flask, 200mL, S/T 24/40 Joint
• KD1949-DC Distilling Column, 12mm IDx300, Vacuum Jacketed (w/o Beads)
• KD1949-C Condenser, Liebig type, S/T 10/30 Top Joint, 100mm

D1963 Specific Gravity of Pigments, Drying Oils, Varnishes, Resins, etc.
• K0C135-10 Pycnometer, 10mL, with Thermometer and Cap
• K0C135-25 Pycnometer, 25mL, with Thermometer and Cap
• K0C135-50 Pycnometer, 50mL, with Thermometer and Cap
• K0C135-100 Pycnometer, 100mL, with Thermometer and Cap

D1966 Determination of Water and Sediment By Centrifuge Method
• KD1966 Centrifuge Tube, Pear-Shape, 100mL with Lower Stem Graduated to 1.5mL in 0.1mL divisions

D2001 Depentanization of Gasoline and Naphthas
• KD2001-A Distillation Column, Jacketed, 13mm ID
• KD2001-B Reflux Condenser Head for Distillation Column
• KD2001-C Trap for Light End Depentanization
• KD2001-D Receiver, Graduated, 12.5mL, S/T 19/38 Male Joint
• KD2001-E Dewar Flask, for Immersion of Receiver
• KD2001-F Flask, Distilling, 100mL, R.B., S/T 24/40 Joint

D2002 Isolation of Representative Saturates Fractions from Low-Olefinic Petroleum Naphthas
• KD2002-C-1 Alternate Analytical Absorption Column, w/top adapter
• KD2002-C Absorption Column, Analytical, Water Jacketed
• KD2002-ER Eluant Reservoir, 250mL, S/J 28/15 Joints with Stopper
• KD2002-R Receiver, 10mL with TFE Stopcock and S/T 14/35 Joint

D2003 Isolation of Representative Saturates Fraction from High-Olefinic Petroleum Naphthas
• KD2003-AC Absorption Column, Water Jacketed, S/J 28/15 and S/T 14/35 Joints
• KD2003-R Receiver, Graduated, 10mL, S/T 14/35 Joint, TFE Stopcock

D2007 Characteristic Groups in Rubber Extender and Processing Oils and other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method
• KD2007-C Clay-Gel Percolating Column (2 required), S/T 24/40, Fritted Disc
• KD2007-F Distillation Flask, 3-neck, 500mL, S/T 24/40 Joint, for Extraction
• KD2007-H Distillation Head with Vigreaux Column, S/T 24/40, TFE Stopcock
• KD2007-CT Connecting Tube from Flask to Column, S/T 24/40 (If ordered with Flask, Head, and Column, Tube can be supplied custom fitted. Otherwise user must heat glass tube to soften and align and conform to fit properly, or install a flexible connection device such as teflon bellows or slip-fit teflon tubing sleeve).
• KD2007-RC Reflux Condenser, S/T 24/40, Friedrichs
• KD2007-B Beaker, Anticreep, 150mL
• KD2007-APC Azobenzene Percolation Column, 12x600mm, 125mL Reservoir
• KD2007-MV Teflon Metering Stopcock for Azobenzene Percolation Column

D2036 Determination of Cyanides in Water
• KD2036 Complete Distillation Apparatus, consisting of 1000mL 2-neck Flask, Cold Finger Condenser, Absorber Trap, Inlet Tube

D2111 Determination of Specific Gravity of Liquid Chemicals, Halogenated Organic Solvents Ethylene Glycols and Propylene Glycols
• K0D891-25 Specific Gravity Bottle for Volatile Liquids, 25mL, Jacketed
• K0D891-50 Specific Gravity Bottle for Volatile Liquids, 50mL, Jacketed

 

D2162 Basic Calibration of Master Viscometers And Viscosity Oil Standards
• KD2162-C1 Cannon Master Viscometer, Approximately 0.001-0.003cSt/s
• KD2162-C3 Cannon Master Viscometer, Approximately 0.003-0.009cSt/s
• KD2162-U1 Ubbelohde Master Viscometer, Approximately 0.001-0.003cSt/s
• KD2162-U3 Ubbelohde Master Viscometer, Approximately 0.003-0.009cSt/s

D2184 Determination of Isotopic Concentration of Heavy Water
• KD2184-P Pycnometer, 25mL, S/T 7/15 Stopper
• KD2184-MS2 Matched Set of two Pycnometers

D2352 Determination of Carbon Dioxide and Sulfur Dioxide in Carbonates
• K0D215 Alkalimeter, Knorr, 250mL Flask, S/T 24/40 and S/T 16

D2363 Testing of Hydroxpropyl Methylcellulose
• KD2363 Complete apparatus for Steam Distillation including Steam Boiler Tube with Inlet Adapter, 25mL Boiling Flask with Side Neck, Vigreaux Column,
• 110mm long Liebig Type Condenser, and Vertical Adapter for delivery (S/T 14/20 Joints) (boiler has S/T 24/40 joints)

D2385 Hydrogen Sulfide and Mercaptan Sulfur In Natural Gas (Cadmium Sulfate Iodometric Titration Method)
• KD2385-GWB Gas Washing Bottle, 70x280mm, Coarse Fritted Disc, S/T 24/40
• KD2385-ST Spray Trap, S/T 24/40 Joint, 65mm OD Bulb

D2420 Hydrogen Sulfide in LP Gases by Lead Acetate Method
• KD2420 Apparatus including Cylinder, Stoppers, Watch Glass and Glass Rod

D2533 Vapor-Liquid Ratio of Spark-Ignition Engine Fuels
• KD2533 Buret, Vapor-Liquid Ratio, Graduated 0 – 35mL

D2549 Separation of Representative Aromatics and Nonaromatics Fractions of High-Boiling Oils by Elution Chromatography
• KD2549-C2 Chromatographic Column, 10x760mm, 100mL bulb, for 2 gram
• KD2549-C10 Chromatographic Column, 15x1150mm, 200mL bulb, for 10 gram

D2569 Distillation of Pitch
• KD2569-F Flask, Distillation, 300mLx131mm tall w/side arm 10x220mm
• KD2569-F Condenser, Air, 13x360mm

D2619 Hydrolytic Stability of Hydraulic Fluids (Beverage Bottle Method)
• K00D96-8 Centrifuge Tube, Conical, A8-Inch (203mm), 100mL

D2717 Thermal Conductivity of Liquids
• KD2717 Thermal Conductivity Cell, Platinum Resistance Thermometer

D2748 Determination of Pyridine Bases in Acids
• KD2748 Distillation Apparatus Consisting of 1000mL Boiling Flask, Bulb Trap Adapter, Connection Adapter, 600mm Liebig Type Condenser, and Lower Drip Adapter, S/T 24/40 Joints

D2780 Solubility of Fixed Gases in Liquids
• KD2780-PS Ambient Pressure Saturator, Glass, 1000mL, S/T 27 Joint, PTFE Stopcock w/O-Rings, Upper Head for Gas Inlet, Outlet and Dispersion Element, and Heating Mantel and Thermocouple wire x 6 ft long
• KD2780-ES Gas Extraction System consisting of KD2780-ES1 through KD2780-ES7
• KD2780-ES1 Reflux Condenser, Liebig, S/T 24/40, 300mm
• KD2780-ES2 Gas Extraction Chamber, 60 x 280mm, S/J 12/2 Joints
• KD2780-ES3 Boiler Flask, 500mL, Round Bottom, S/J 35/25 Socket Joint, with Adapter, 35/25 x 12/2 S/J Joint
• KD2780-ES4 Gas Buret, Water Jacketed, 100mL, with 3-Way, TEE Bore Stopcock and S/J 12/2 Joint
• KD2780-ES5 Leveling Bulb, 500mL
• KD2780-ES6 Connecting Manifold with 3 – TFE 120 Degree Stopcocks
• KD2780-ES7 Manometer, Open End, 1-Meter, S/J 12/2 Connection

D2879 Vapor Pressure-Temperature Relationship and Initial Decomposition Temperature of Liquids by Isoteniscope
• KD2879 Isoteniscope Pressure Manometer, 8mm Od x 500mm w/bulb

D2886 Vacuum Trap
• KD2886 Vacuum Trap, 22x125mm, Inlet & Outlet Arms 10mm OD

D2892 Distillation of Crude Petroleum (15- Theoretical Plate Column)
• Quotations submitted on request. Specify Type, Scale, and Sizes of Components Required.

D2910 Extraction Apparatus
• KD2910 Complete Extraction Apparatus consisting of 3000 mL Solvent Flask, Extractor Body with Extraction Chamber, Siphon Tube, Removable Filter and Top Lid, and Allihn Condenser 250mm. Joints are S/T 45/50
D2912 Oxidant Content of Atmosphere
• KD2912 Impinger, Midget, S/T 24/40, 25mm Body, 5mm Inlet, 1mm Nozzle, Body Graduated 0-25mL in 5mL Divisions

D2913 Mercaptan Content of Atmosphere
• KD2913 Impinger, Midget, S/T 24/40, 25mm Body Graduated to 25mL in 5mL Divisions, 5mm ID inlet, Coarse Fritted Pencil at Tip

D2914 Oxidant Content of Atmosphere
• KD2912 Impinger, Midget, S/T 24/40, 25mm Body, 5mm Inlet, 1mm Nozzle, Body Graduated 0-25mL in 5mL Divisions

D2972 Determination of Arsenic in Water
• KD2972 Arsenic Determination Apparatus consisting of 125mL Erlenmeyer Flask, Scrubber Tube, and Absorber Tube,
S/T 24/40 and S/J 12/2

D3120 Trace Quantities of Sulfur in Light Liquid Petroleum Hydrocarbons by Oxidative Microcoulometry
• KD3120 Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum

D3234 Abrasion Resistance of Petroleum Wax Coatings
• KD3234-T Glass Tube, 1″ ID x 12″ Long, with Support Device for #12 Sieve
• KD3234-S Screen Sieve, Size #12, cut 1″ Diameter
• KD3234-F Separatory Funnel, 500mL, 4mm TFE Stopcock, Stem Cut Short

D3242 Acidity in Aviation Turbine Fuel
• KD3242 Titration Flask, 500mL, Erlenmeyer Shape, with Inlet Tube

D3246 Sulfur in Petroleum Gas By Oxidative Microcoulometry
• KD3120 Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum

D3431 Trace Nitrogen in Liquid Petroleum Hydrocarbons (Microcoulometric Method)
• KD3120 Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum

D3505 Density of Liquid Hydrocarbon Materials
• K0D941 Pycnometer, Side Arm Type, 4.5 ±0.5mL, Weight less than 30g

D3608 Sampling Low Concentrations of Nitrogen Dioxide
• KD1607 Gas Bubbler Apparatus, S/T 29/42, S/J 18/7, Coarse Pencil Fit

D3712 Analysis of Oil-Soluble Petroleum Sulfonates by Liquid Chromatography
• KD3712-C Chromatographic Column, 22 x 300mm w/250mL Reservoir, 28/15
• KD3712-P Pycnometer for Determining Specific Gravity, 50mL ±1.0mL

D3825 Dynamic Surface Tension by the Fast-Bubble Technique
• KD3825 Glass Bubbler Unit, Jacketed, without Pressure Transducer

D3831 Manganese in Gasoline by Atomic Absorption Spectrometry
• KD3831 Automatic Pipette, 9.0mL, with Auto-zero and TFE Stopcock

D3867 Test for Nitrite-Nitrate in Water
• KD3867 Cadmium Reduction Column, 5x200mm, 85mL Reservoir

D3904 Oil from Oil Shale (Resource Evaluation by the USBM Fischer Assay Procedure)
• KD3904-R Receiver, 100mL Centrifuge Tube, Pear Shape
• KD3904-A Adapter, S/T 24/40, to Receive Product from Retort
• KD3904-C Condenser, Allihn, 300mm, S/T 24/40

D3907 Testing Fluid Cracking Catalysts by Microactivity Test
• KD3907-R Glass Reactor body, 18mmx376mm, S/T 28/15 and 12/5 O-ring Joints
• KD3907-PR Product Receiver, Liquid, S/T 12/5 O-ring Joints

D3908 Hydrogen Chemisorption on Supported Platinum on Alumina Catalysts by Volumetric Vacuum Method
• KD3908 Sample Cell, S/T 10/30 Joints, 2mm Vacuum Stopcocks

D3945 Shear Stability of Polymer-Containing Fluids Using a Diesel Injector Nozzle
• KD3945-CV Cooling Vessel, Jacketed, 25mm IDx180mm long, TFE Stopcock
• KD3945-FR Fluid Reservoir, 250mL, w/Distributor Plateand 3-way Stopcock

D4006 Water in Crude Oil by Distillation
• KD4006-A Distillation Trap, 5mL in 0.05
• KD4006-B Drying tube for Distillation Apparatus
• KD4006-C Condenser, 400mm, Liebig, S/T 24/40
• KD4006-F Flask, 1000mL, S/T 24/40, Round Bottom

D4180 Vibratory Packing Density of Formed Catalyst Carriers
• KD4180 Feed Funnel, 100mm x 20mm ID

D4484 Inorganic Particles in Marine Residual Fuel Oils by Selective Centrifugal Separation
• KD2709 Centrifuge Tube, Conical, 100mL, Tip Graduated to .05mL in .01 Divisions

D4486 Kinematic Viscosity of Volatile and Reactive Liquids
• KD4486 Viscometer for Vulnerable Liquids (specify approximate constant)

D4512 Vibrated Apparent Packing Density of Fine Catalyst Particles and Powder
• KD4180 Feed Funnel, 100mm x 20mm ID

D4629 Organically Bound Trace Nitrogen in Liquid Petroleum Hydrocarbons by Oxidative Combustion and Chemilluminescence Detection
• KD4629 Pyrolysis Tube, Quartz, S/J 18/9 Ball outlet, 6mm Inlets, Septum

D4814 Automotive Spark-Ignition Engine Fuel
• KD2533 Buret, Vapor-Liquid Ratio, Graduated, 0-35mL

D4871 Guide for Universal Oxidation/ThermalStability Test Apparatus
• KD4871-TC Test Cell, 38 x 300mm, S/T 34/45 Joint
• KD4871-C Condenser, Allihn, 330mm, S/T 34/45 Joint, Top 9mm ID
• KD4871-G11 Gas Inlet Tube, 8x850mm with Capillary Tip (no Support Ring)
• KD4871-G11A Alternate Gas Inlet Tube, 8x850mm with Capillary Tip but w/Support Ring
• KD4871-G12 Gas Inlet Tube, 8x455mm, Capillary Tip, Top Bent 90 Degrees
• KD4871-BH Basic Head, S/T 34/45 Joint, Septum Port, Screw Cap Joint
• KD4871-1H Intermediate Head, S/T 34/45, 170mm long, Septum Port
• KD4871-SH Sampling Head, S/T 34/45 x 175mm long, Septum Port
• KD4871-SR Support Ring, 9.5mm IDx12.7mm ODx7mm long with 4 Hooks
• KD4871-SP Spacer Ring, 9.5 mm ID x 12.7mm OD x 7mm Long